CDPRQ - TEKUSOLV II, 0945
- MSDS: CDPRQ
- Manufacturer: CERTIFIED LABS
- Product Name: TEKUSOLV II, 0945
- National Stock Number: 6850-00N074191
Product Identification
Product ID:TEKUSOLV II, 0945
MSDS Date:09/29/1995
FSC:6850
NIIN:00N074191
MSDS Number: CDPRQ
Responsible Party
US
Emergency Phone: 214-438-1381
Info Phone: 214-438-1381
Preparer: C KERINS
Cage: 0A649
Contractor
Telephone: 214-438-1381972-438-1381
Cage: 53417
Ingredients
CYCLOHEXENE, 1-METHYL-4-(1-METHYLETHENYL)-, (R)-;
CAS: 5989-27-5
RTECS: GW6360000
OSHA PEL N/K
ACGIH TLV: N/K
1-TETRADECENE
CAS: 1120-36-1
OSHA PEL N/K
ACGIH TLV: N/K
DRAINAGE SYSTEMS AND BODIES OF WATER.
RTECS: 9999999ZZ
INJURY/DEATH WHEN EXPOSED TO HEAT, HOT SURF,
RTECS: 9999999ZZ
Hazards
LD50 LC50 Mixture:SEE INGREDIENT 1.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: EYE: CAUSES IRRIT SUCH AS
REDNESS & TEARING. SKIN: MAY CAUSE IRRIT & MAY LEAD TO SENSIT IN
INDIVIDUALS SENSITIVE TO PRODS CONTAINING ORANGE OIL.
FREQUENT/PRLNG SKIN CONT CAN LEAD TO REDNESS & D ERM. INHAL: MAY BE
IRRIT TO RESP TRACT.INHAL OF HIGH CONCS OF VAP DUE TO ELEVATED
TEMPS CAN CAUSE (EFTS OF OVEREXP)
Explanation of Carcinogenicity:NOT RELEVANT.
Effects of Overexposure:HLTH HAZ: ANESTH, DROW, UNCON, CNS EFTS &
DEATH. INGEST: SML AMTS OF THIS PROD ASPIRATED INTO RESP SYS DURING
INGEST/VOMIT MAY CAUSE CHEM PNEUMIT WHICH CAN BE FATAL. INGEST MAY
CAUSE DROW. CHRONIC: NO CHRONIC DATA AVAIL. TARGET ORGANS: CNS.
Medical Cond Aggravated by Exposure:PREEXISTING SKIN AND RESPIRATORY
DISORDERS.
First Aid
First Aid:INHAL: REMOVE TO FRESH AIR. SEEK MED ATTN IF RESP IRRIT
DEVELOPS/IF BRTHG BECOMES DFCLT. EYE: IMMED RINSE W/WATER. REMOVE
ANY CONT LENSES & CONTINUE FLUSHING FOR AT LEAST 15 MIN. HOLD
EYELIDS APART TO ENSURE RINSING OF ENTIRE SURF OF EYES & LIDS
W/WATER. GET IMMED MED ATTN. SKIN: WASH AFFECTED AREAS W/PLENTY OF
SOAP & WATER FOR SEVERAL MIN. REMOVE & CLEAN CONTAM CLTHG & SHOES.
SEEK MED (SUP DAT)
Fire Fighting
Flash Point Method:PMCC
Flash Point:201F,94C
Extinguishing Media:FOAM, CARBON DIOXIDE, DRY CHEMICAL.
Fire Fighting Procedures:WEAR NIOSH APPRVD SCBA & FULL PROT EQUIP .
COOL FIRE-EXPOSED CONTRS W/WATER SPRAY TO PVNT BURSTING. DO NOT USE
A DIRECT STREAM OF WATER AS (SUP DAT)
Unusual Fire/Explosion Hazard:VAPORS ARE HEAVIER THAN AIR AND MAY
TRAVEL TO DISTANT SOURCES OF IGNITION AND FLASHBACK. PRODUCT MAY
PRODUCE A FLOATING FIRE HAZARD AS LIQUID FLOATS ON WATER.
Accidental Release
Spill Release Procedures:ELIM ALL SOURCES OF IGNIT. DIKE & CONTAIN
SPILL IF SAFE TO DO SO. COVER W/INERT ABSORB MATL & TRANSFER MATL
INTO PROPERLY LABELED CONTRS FOR DISP. SPILLED MATL MAY BE
SLIPPERY. PVNT PROD FROM CONTAMIN ATING SOIL/FROM ENTERING SEWAGE &
(ING 3)
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.
Handling
Handling and Storage Precautions:STORE INDOOR BETWEEN 0F & 100F. KEEP
CONTRS CLSD WHEN NOT IN USE. USE W/CAUTION AROUND HEAT, SPKS, PILOT
LIGHTS, STATIC ELEC & OPEN FLAME.
Other Precautions:DO NOT PRESSURIZE, CUT, WELD, SOLDER, DRILL,
GRIND/EXPOSE EMPTY CONTRS TO HEAT, HOT SURF, SPKS/OPEN FLAMES. KEEP
OUT OF REACH OF CHILDREN. READ ENTIRE LABEL BEFORE USING PROD.
EMPTY CONTRS RETAIN PROD RESIDUE & MAY EXPLODE & CAUSE (ING 4)
Exposure Controls
Respiratory Protection:NORMALLY NOT NEEDED AT AMBIENT TEMPERATURES. USE
NIOSH APPROVED SUPPLIED-AIR RESPIRATORY PROTECTION IN CONFINED OR
ENCLOSED SPACES.
Ventilation:GENERAL EXHAUST TO PROTECT WORKERS FROM EXPOSURE AT POINTS
OF VAPOR EVOLUTION.
Protective Gloves:NEOPRENE RUBBER OR NITRILE GLOVES.
Eye Protection:ANSI APPRVD CHEM WORKERS GOGGLES .
Other Protective Equipment:ANSI APPRVD EMER EYEWASH & DELUGE SHOWER .
SOLV-RESIST APRON/OTHER IMPERVIOUS CLOTHING TO MINIMIZE SKIN
CONTACT.
Work Hygienic Practices:NONE SPECIFIED BY MANUFACTURER.
Supplemental Safety and Health
FIRE FIGHT PROC: SPATTERING MAY RSLT. FIRST AID PROC: ATTN IF IRRIT
DEVELOPS. INGEST: GIVE 3-4 GLASSES OF WATER, BUT DO NOT INDUCE
VOMIT. IF VOMIT OCCURS, GIVE FLUIDS AGAIN. GET IMMED MED ATTN IF
DISC OMFORT OCCURS. NOTES TO MD: INGEST & SUBSEQUENT VOMIT CAN LEAD
TO ASPIR INTO LUNGS WHICH CAN CAUSE DMG & MAY BE FATAL.
Chemical Properties
Boiling Pt:B.P. Text:463F,239C
Vapor Pres:0.13
Vapor Density:5.2
Spec Gravity:0.772 (H*2O=1)
Evaporation Rate & Reference:<0.1 (BUTYL ACETATE=1)
Solubility in Water:NEGLIGIBLE
Appearance and Odor:COLORLESS TRANSPARENT, ORANGE ODOR
Percent Volatiles by Volume:100
Stability
Stability Indicator/Materials to Avoid:YES
OXIDIZERS, ACIDS, CLAYS AND IODINE PENTAFLUOROETHYLENE.
Stability Condition to Avoid:AVOID HEAT, HOT SURFACES, SPARKS AND OPEN
FLAMES.
Hazardous Decomposition Products:OXIDES OF CARBON, FUMES AND ACRID
SMOKE.
Disposal
Waste Disposal Methods:DISPOSE OF IN ACCORDANCE WITH ALL LOCAL, STATE
AND FEDERAL REGULATIONS.
Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.